Products
Steam Boilers
Model IS100V, IS200V, IS300V, IS400V, IS600V, IS800V
Thermic Fluid Heater
Model IF100V, IF200V, IF400V, IF600V/H, IF1000V/H, IF1500V/H
Water Heater
Model IW100V, IW200V, IW400V, IW600V/H, IW1000V/H, IW1500V/H
Air Heater
Model IA70V, IA100V, IA150V, IA200V, IA300V/H, IA400V/H
Process heating equipments in our manufacturing range are coil-type, a forced through circulation type and capable of quick starting and stopping. Since there is no storage of kinetic energy there is no scope for explosion hazard in our products. All the burners are pressure jet, forced draught, spark ignited and fully automatic. All of our equipments are equipped with all kinds of safeties controls making it fully automatic and safer.
Coils: - the unique multi-start coil is designed to offer minimum pressure drop allowing it to consume low power for optimum mass circulation. The double coil assembly is designed to achieve 3 passes of fuel gasses and maximum resident time and therefore making the highest possible heat transfer. This makes the equipment energy efficient consistently. The jacket between inner and outer shell and aluminum heat refractor is provided to preheat the combustion air by utilizing the waste heat and keeps the outer surface of the outer shell cool without insulation.
A feed-water, preheated, cum waste heat recovery unit, makes our steam boilers 4 pass and therefore a super fuel savior. The waste heat recovery unit has an inbuilt bypass duct and an isolating damper, to felicitate bypassing the same in an event of abnormal working to avoid down time.
All our products are available in vertical and horizontal version to suite customer’s site conditions.